{"id":8484,"date":"2022-01-18T12:59:20","date_gmt":"2022-01-18T12:59:20","guid":{"rendered":"http:\/\/www.optimaaero.pl\/en\/?p=8484"},"modified":"2022-07-20T04:56:15","modified_gmt":"2022-07-20T04:56:15","slug":"analiza-potencjalnych-kolizji-z-roslinnoscia","status":"publish","type":"post","link":"https:\/\/www.optimaaero.pl\/en\/analiza-potencjalnych-kolizji-z-roslinnoscia\/","title":{"rendered":"Analysis of potential collisions with vegetation"},"content":{"rendered":"<section class=\" no-padding md-no-padding sm-no-padding xs-no-padding\"><div class=\"container\"><div class=\"wpb_column brando-column-container  vc_col-sm-12 vc_col-md-12 vc_col-xs-12 no-padding md-no-padding no-margin md-no-margin\" data-front-class=\"brando-column-container  no-padding md-no-padding no-margin md-no-margin\"><div class=\"vc-column-innner-wrapper\"><div class=\"wpd-innner-wrapper\"><p>We acquire data in a fast and precise way within the power grids running along forest areas, including places that are difficult to access for traditional measurements. Using aerial laser scanning, we can also perform measurements at night and in low-light conditions.<\/p>\n<p>Our surveys make it possible to detect collisions between trees and power lines, both at the stage of planning maintenance work and repairing faults.<\/p>\n[vc_empty_space height=\"44px\"][vc_gallery type=\"nivo\" interval=\"3\" images=\"10516,10517,10518\" img_size=\"full\" onclick=\"\"]<\/div><\/div><\/div><div class=\"wpb_column brando-column-container  vc_col-sm-12 vc_col-md-12 vc_col-xs-12\" data-front-class=\"brando-column-container \"><div class=\"vc-column-innner-wrapper\"><div class=\"wpd-innner-wrapper\"><p>Aerial techniques allow us to quickly reach the inspection site and take detailed measurements. The scanner used accurately records the condition of the network along with the terrain under and adjacent forests and individual trees.<\/p>\n<p>The result is a spatial digital documentation, on the basis of which it is possible to perform an analysis of the existing condition, measure horizontal and vertical distances accurately, determine approach zones and plan work in advance.<\/p>\n<p>On the basis of the acquired data, it is possible to identify precisely the places where in the near future the crown of trees may dangerously approach the line and cause power outages.<\/p>\n<p>Objects located at a preset distance under the wires or a buffer of a preset radius around the wires can be identified. Potentially dangerous places can be rearranged with a specific color directly on the point cloud or in tabular form, with given coordinates in a preset coordinate system and the distance of the crowns of trees or other objects from the wire.<\/p>\n<p>In case of emergency situations (windstorms, storms, damage), a quick inspection can be performed to speed up localization and assess the extent and nature of damage.<\/p>\n<\/div><\/div><\/div><\/div><\/section><section><div class=\"container\"><div class=\"wpb_column brando-column-container  vc_col-sm-12 col-xs-mobile-fullwidth\" data-front-class=\"brando-column-container  col-xs-mobile-fullwidth\"><div class=\"vc-column-innner-wrapper\"><div class=\"wpd-innner-wrapper\"><p><strong>CHARAKTERYSTYKA CHMURY PUNKT\u00d3W:<\/strong><\/p>\n\n<table id=\"tablepress-29a\" class=\"tablepress tablepress-id-29a\">\n<tbody>\n<tr class=\"row-1 odd\">\n\t<td class=\"column-1\">Point cloud density (LiDAR)<\/td><td class=\"column-2\">~400 pts\/m2<\/td>\n<\/tr>\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">Point cloud density (photogrammetry)<\/td><td class=\"column-2\">~2500 pts\/m2<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Accuracy<\/td><td class=\"column-2\"><3 cm<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Data format<\/td><td class=\"column-2\">LAS \/ LAZ \/ E57 \/ TXT<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Color palette<\/td><td class=\"column-2\">RGB \/ monochromatic \/ by elevation<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Classification<\/td><td class=\"column-2\">ASPRS standard<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\">Coordinate System<\/td><td class=\"column-2\">adapted to project<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-29a from cache -->\n[vc_empty_space height=\"20px\"]<p><strong>ORTHOPHOTO CHARACTERISTICS:<\/strong><\/p>\n\n<table id=\"tablepress-27a\" class=\"tablepress tablepress-id-27a\">\n<tbody>\n<tr class=\"row-1 odd\">\n\t<td class=\"column-1\">Data format<\/td><td class=\"column-2\">GeoTIFF \/ JPEG \/ PDF<\/td>\n<\/tr>\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">Ground Sampling Distance<\/td><td class=\"column-2\">od 1 cm<\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Accuracy<\/td><td class=\"column-2\"><3 GSD<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Coordinate System<\/td><td class=\"column-2\">adapted to project<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Color palette<\/td><td class=\"column-2\">24 bit RGB<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Compression<\/td><td class=\"column-2\">LZW \/ JPEG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-27a from cache -->\n[vc_empty_space height=\"20px\"][vc_raw_html]JTNDc2NyaXB0JTNFJTBBJTIwJTIwZG9jdW1lbnQud3JpdGUlMjglMjclM0NhJTIwaHJlZiUzRCUyMiUyNyUyMCUyQiUyMGRvY3VtZW50LnJlZmVycmVyJTIwJTJCJTIwJTI3JTIyJTNFJTNDYiUzRSUzQyUyMEdPJTIwQkFDSyUyMFRPJTIwUFJFVklPVVMlMjBQQUdFJTNDJTJGYiUzRSUzQyUyRmElM0UlMjclMjklM0IlMEElM0MlMkZzY3JpcHQlM0U=[\/vc_raw_html]<\/div><\/div><\/div><\/div><\/section><section style=\"background-color:#efefef;\"><div class=\"container\"><div class=\"wpb_column brando-column-container  vc_col-sm-12 col-xs-mobile-fullwidth\" data-front-class=\"brando-column-container  col-xs-mobile-fullwidth\"><div class=\"vc-column-innner-wrapper\"><div class=\"wpd-innner-wrapper\"><h1 class=\"alt-font heading-style7 \"><span class=\"crimson-red-text\" style=\"color:#e8cd20\">\/<\/span> OTHER FROM ENERGETICS<\/h1><p><strong>Power lines:<\/strong><\/p>\n<ul>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/inwentaryzacja-napowietrznych-linii-elektroenergetycznych\/\">powerlines inventory<\/a><\/li>\n<\/ul>\n<p style=\"text-indent: 50px; line-height: 14px;\">- powerlines modeling<\/p>\n<p style=\"text-indent: 50px; line-height: 14px;\">- calculating catenary parameters<\/p>\n<p style=\"text-indent: 50px; line-height: 14px;\">- powerlines profiles<\/p>\n<ul>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/analiza-potencjalnych-kolizji-z-roslinnoscia\/\">analysis of potential collisions with vegetation<\/a><\/li>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/inspekcje-linii-elektroenergetycznych\/\">powerlines inspections<\/a><\/li>\n<\/ul>\n<p><strong>Electricity stations \/ traction substations:<\/strong><\/p>\n<ul>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/wysokorozdzielcze-ortofotomapy-i-modele-rastrowe\/\">high-resolution orthophotomaps and raster elevation models<\/a><\/li>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/chmury-punktow\/\">point clouds<\/a><\/li>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/fotorealistyczne-modele-3d-stacji\/\">photorealistic 3D models<\/a><\/li>\n<li><a href=\"http:\/\/www.optimaaero.pl\/en\/inspekcje-wizyjne-stacji-elektroenergetycznych\/\">station inspections<\/a><\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/section>","protected":false},"excerpt":{"rendered":"<p>We acquire data in a fast and precise way within the power grids running along forest areas, including places that are difficult to access for traditional measurements. Using aerial laser scanning, we can also perform measurements at night and in low-light conditions. Our surveys make it possible to detect collisions between trees and power lines, [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_mi_skip_tracking":false,"footnotes":""},"categories":[33],"tags":[],"class_list":["post-8484","post","type-post","status-publish","format-standard","hentry","category-energetyka"],"_links":{"self":[{"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/posts\/8484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/comments?post=8484"}],"version-history":[{"count":19,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/posts\/8484\/revisions"}],"predecessor-version":[{"id":12731,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/posts\/8484\/revisions\/12731"}],"wp:attachment":[{"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/media?parent=8484"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/categories?post=8484"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.optimaaero.pl\/en\/wp-json\/wp\/v2\/tags?post=8484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}